Title of Activity
- Test project
Objective
- To make sure the project functionality
Content / Procedure
The project is ready for a test |
Problem Statement
- The LCD did not display anything and the vibrator not function
Solution
- Change the power supply for IC regulator L7805CV
- Change the output device for vibrator because the vibrator is very sensitive.
Analysis
LCD display NORMAL |
After the IC regulator have been changed,the output from LCD are successfully displayed.After the IC is burned with the new program,the output vibrator also functioning well. This program flow are focusing on 3 different mode which is when the mercury switches are in normal mode,it mean that the drivers are not sleepy. For the 2nd mode, when the mercury is not linear within 3 second the LCD will display "MENGANTUK" and that means the driver is falling asleep while driving and the 3rd mode is "PEMANDU PENGSAN" when the mercury is not linear more than 3 second and the GSM will send the user a message to tell that the driver are asleep or fainted.
The LCD display mode 2 "MENGANTUK" |
Conclusion
As a conclusion,student are able to identify and trouble shoot the problem on the circuit. From this task, student get to gain more knowledge indirectly while troubleshooting it.